Products Details

ATS Bending Beam Rheometer

Description:

Bending Beam Rheometers (BBR) by ATS measure the flexural creep stiffness of asphalt binder from ambient to -40°C to predict low-temperature thermal cracking of asphalt pavements. Special molds form small beam samples of binders for testing, and the deflection of the beam is recorded as a constant load is applied. Load, displacement, and bath temperature are displayed in real-time via tabular and graphic forms.

Both models use an air-bearing system to ensure reliable loading with accurate and repeatable results. A linear variable displacement transducer (LVDT) with a range of 6.35mm and accuracy of ±2µm measures deflection. The stainless steel three-point bend apparatus is easily removed and reinstalled in the base unit for convenient sample preparation and loading.

A fluid bath controls the temperature of the Ethylene Glycol/Water/Methanol mixture down to -40°C (-40°F). Process temperature is controlled by two independent platinum RTD temperature transducers to maintain stability. Both models fully comply with ASTM/AASHTO requirements. A source of clean, dry, compressed air at 50 PSIG minimum must be provided by the user.

Models come with five aluminum specimen Molds with mylar strips, a Calibration Kit with required weights, and a Confidence Beam. Calibrated test weights and a certified LVDT NIST-traceable standard are also provided.

HM-59 Models operates through an included desktop computer system with pre-loaded control, data acquisition, and analysis software. The computer system includes a monitor, keyboard, and mouse. Safe, rapid cooling of the test fluid is provided by the mechanical refrigeration system.

HM-73 Models retains all of the performance features of the HM-59 but incorporates a state-of-the-art touchscreen design for easy setup and operation. The touchscreen controller has walk-through menus for guidance and the machine can be started, stopped, and monitored remotely through an App installed on a smartphone, iPad, or tablet. The user-friendly control, acquisition, and analysis software is preloaded on the internal computer and allows daily verification and periodic calibration of the load cell, LVDT, and RTD transducers. A USB port is located on the front of the unit for software upgrades and data storage.

Features:

  • Both models are fully compliant with ASTM and AASHTO requirements
  • The optimal solution for predicting low-temperature thermal cracking of asphalt pavements via flexural creep stiffness measurements
  • Air-bearing systems ensure repeatable results and reliable loading
  • Fluid baths accurately control the temperature of the Ethylene Glycol/Water/Methanol mixture down to -40°C (-40°F)

Included Items:

  • Computer or Touchscreen Operated ATS Bending Beam Rheometer (115V, 50/60Hz or 230V, 50/60Hz)
  • Five aluminum specimen molds with mylar strips
  • Calibration Kit with required weights and Confidence Beam
  • Calibrated test weights
  • Certified LVDT NIST-traceable standard

Accessories:

  • HMA-348R Aluminum BBR Beam Molds are used in cold temperatures to measure the flexural creep stiffness of asphalt binder
  • HMA-347 Mylar Strips adhere to the BBR mold and allow for easier sample extraction after testing

Specifications:

Temperature RangeAmbient to -40°F (-40°C)
Electrical

HM-59 and HM-73: 115V, 50/60Hz, 2 amps, 1-phase

HM-59F and HM-73F: 230V, 50/60Hz, 2 amps, 1-phase

Product Dimensions49 x 49x 41in (1,245 x 1,245 x 1,040mm) WxDxH
Estimated Shipping Weight

HM-59: 379.0lb (171.91kg)

HM-59F: 379.0lb (171.91kg)

HM-73: 390.0lb (176.90kg)

HM-73F: 390.0lb (176.90kg)